• 兴发娱乐

    替换
    Infusion System

    BeneFusion 5 Series

    SAFE Infusion

    With years of deep insights into clinical needs, Mindray develops the BeneFusion 5 Series infusion pump system. It is set to redefine the SAFE Infusion through various safety features, and more importantly, through a brand new concept it creates regarding SAFE infusion: Smart system, Accurate infusion, Friendly design, and Easy connection.

    glp23-s2-1
    Smart System
    Intelligent Occlusion Management
    • Dynamic Pressure System (DPS) that monitors the pressure with numeric and graphic illustration can help caregivers identify occlusion in advance to prevent potential risks.
    Dose Error Reduction System (DERS)
    • The DERS Drug Library with color-coded drug names helps to minimize the risk of medication errors. Meanwhile, an alert will be activated when the soft/hard limit is reached to prevent potentially fatal over-infusions or under-infusions, enabling caregivers to adopt standard practices on drug concentrations and dosing units for improved patient safety.
    glp23-s3
    Accurate Infusion
    Consistent and Precise Performance
    • Real-time high stability of infusions guaranteed by the overall mechanical accuracy;
    • High accuracy over long hours guaranteed by the compensatory algorithm to deformed IV sets.
    High Accuracy Detection Sensors
    • Assist in identifying risks caused by occlusion and air bubbles to ensure patient safety during the infusion.
    glp23-s4
    Friendly Design
    Quick Guide
    Quickly master correct operations
    glp23-s5-1
    Graphical Alarm Display
    Trace and correct issues timely
    glp23-s5-2
    Total Volume Collection
    Record the infused volume with ease
    glp23-s5-3
    DS5 Docking Station
    Integrated cable management, seamless data integration and synergy, multi-channel relay
    glp23-s5-4
    Next
    Previous
    Easy Connection

    Seamless Integration and Synergy

    • Infusion info can be synchronized and viewed on the display of the BeneVision N Series patient monitor.
    • With a comprehensive picture of infusion data and physiological parameters, it facilitates fast and accurate clinical decision-making and reasonable prescribing.
    glp23-s7
    BeneFusion CS5 Central Infusion Supervision System\r\n
      \r\n
    • BeneFusion CS5 central infusion supervision system is an intelligent central infusion supervision system with real-time patients’ infusion status display.
    • \r\n
    • Draw ward function to display actual location of any beds in ward.
    • \r\n
    • Centrally monitor the infusion status and real-time information of all patients.
    • \r\n
    • Patient management, support at least 20000 patients infusion information, alarm event and treatment record review.
    • \r\n
    • Drug library management.
    • \r\n
    • Monitor alarm information system of all wards.
    • \r\n
    • Save and export data.
    • \r\n
    • Support BeneFusion DS5/CS5, infusion/syringe pump software upgrade.
    • \r\n
    • Connect local or network printer to print out.
    • \r\n
    \r\n"}}" id="text-6f7002b685" class="8f00b2 cmp-text">

    BeneFusion CS5 Central Infusion Supervision System

    • BeneFusion CS5 central infusion supervision system is an intelligent central infusion supervision system with real-time patients’ infusion status display.
    • Draw ward function to display actual location of any beds in ward.
    • Centrally monitor the infusion status and real-time information of all patients.
    • Patient management, support at least 20000 patients infusion information, alarm event and treatment record review.
    • Drug library management.
    • Monitor alarm information system of all wards.
    • Save and export data.
    • Support BeneFusion DS5/CS5, infusion/syringe pump software upgrade.
    • Connect local or network printer to print out.
    BeneFusion SP5 TCI/ DTCI
    • Smart TCI mode and TIVA mode helping anesthetists concentrate on patient during operation.
    • 4 anesthetics and 7 protocols suitable for both adult and pediatric.
    • Professional algorithm presenting precise effect site/plasma concentration trend.
    • Automatic drug compensation ensuring exact target concentration.
    • Intuitive operation for step-by-step setting process reducing the mis-operation rate.
    glp23-s8