    BC-7600 Series Auto Hematology Analyzers
    Auto Hematology Analyzers

    BC-7600 Series

    One Tube, One Process with Maximum Efficiency

    One Tube, One Process with Maximum Efficiency

    BC-7600 Series Auto Hematology Analyzers provide comprehensive solutions for complete blood count (CBC), differential white blood cell count (DIFF), hematological malignant cells, low-value WBC/PLT, PLT clumps, etc. They also support the analysis of body fluids.

    BC-7600 Series adopts SF-Cube principal, which has a good correlation with other Series for cross-checking of patient results.

    Comprehensive Solution for Accurate PLT Results

    High Sensitivity and Specificity of Blast Flagging Capability for Preliminary Screening

    The coordinated analysis technology of WNB and DIFF scattergarms give sensitive alerts for “Blasts" with high specificity to reduce unnecessary labor-intensive manual microscopy.

    DIFF 3D scattergram

    Coordinated analysis

    WNB 3D scattergram

    Blasts
    Abn. Lymph/blast?
    Abn. Promyelocyte/blast?

    The detection concentration is as low as 0.03×10⁹/L

    Flag Towards Precise Screening of Infectious Mononucleosis (IM)

    DIFF 3D scattergram

    3D Scattergram of typical infectious mononucleosis

    Alert precisely for reactive lymphocytosis caused by infectious mononucleosis

    through the distribution characteristics of scatter plots

    Reactive Lymph-IM?
    Higher Specificity for Hematological Malignant Cells

    By using the HMC scattergram and combining information from the DIFF and WNB scattergrams, precise alarms for blast cells, abnormal lymphocytes, and abnormal promyelocytes are achieved, effectively aiding clinical diagnosis.

    The specificity has been improved by approximately 40% compared to CD mode.

    Abnormal promyelocyte

    Blast

    Abnormal lymphocyte

    Others

    Typical samples of
    acute promyelocytic leukemia (APL)

    Blasts

    Abn. promyelocyte?

    Typical samples of
    acute monocytic leukemia (M5)

    Blasts

    Typical samples of
    hairy cell leukemia

    Abn. Lymph?

    Blasts

    HMC 3D scattergram

    Comprehensive Solution for Accurate PLT Results

    Brand new PLT-H in every CD test
    PLT-O with Multiple Counting for Low-count Platelet

    There is no need to re-aspirate samples. The instrument will automatically conduct 8 times statistical analysis on low PLT count samples to improve the detection accuracy.

    Scattergram before and after Auto 8x PLT-O counting

    PLT-O with automated PLT-clumps de-aggreation technology

    It solves the problem of falsely low PLT count samples caused by EDTA induced pseudo-thrombocytopenia.

    Automatic retraction and re-testing with PLT-O

    CBC + DIFF + ESR in one test provide reliable ESR results with greater ease
    The BC-7600 series integrates an automatic ESR module in a hematology analyzer. It can also generate both CBC & ESR results in one test within 40 seconds. In addition, it saves the costs that would otherwise be incurred for the purchase, maintenance, consumables, and storage space of a separate ESR analyzer. Compared with the traditional Westergren method, this method performs better in quality traceability, repeatability, speed, safety, and level of automation.
    Accurate
    Cost-effective
    Automatic
    Great correlation with the Westergren method
    Same QC and calibrator as in the BC-6800Plus Series
    Combined examination helps to avoid the interferences of dehydration, polycythemia vera and anemia on ESR results
    BC-7600 Series Auto Hematology Analyzers - High correlation coefficient between Easy-W ESR and Westergren method
    The integrated instrument is capable of both CBC and ESR detection
    Takes up the space of only one analyzer
    BC-7600 Series Auto Hematology Analyzers
    Report CBC + ESR results together in 40 seconds
    Standardize the testing process and reduce the instability of testing
    Automation can reduce the biosafety hazards that may otherwise be introduced by a manual method
    BC-7600 Series Auto Hematology Analyzers - automation ESR test results